Electronic Blood Pressure Meter 

Place of Origin: Hebei, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: SMZ-X2

Display system: Large LCD with digital display system
Measuring method: Oscillography method, automatic inflation, automatic measurement

Display system: Large LCD with digital display system
Measuring method: Oscillography method, automatic inflation, automatic measurement,
 60 times memory with time and date display. 
Pressurization: automatic air inflation by an air pump
Deflation: automatic exhaust
Cuff size: 146 mm ~ 466 mm
Machine size: 135mm×93mm×60mm
Weight: 355g 
Measuring accuracy: ±3mmHg for Pressure
Blood pressure measuring range: 0 to 300mmHg    
Pulse rate range: 40~160 beats/minuter 
Pulse rate accuracy: Within ± 5%
Power source: 4 "AA" batteries (or AC Adapter)
Battery life: Approx.1500 times when used twice a day with new "AA" alkaline batteries
Automatic power off: Automatically power off after 1 minute if nonuse to save energy 
Inflating rate: within the pressure range of (12-30) Kpa or (90-150) mmHg, the inflating rate should be within the range of (0.27 Kpa-0.81 Kpa) or (2-6) mmHg.
Inflating time: the inflating time is about 60 seconds for pressurizing from (0 Kpa) to (26.7 Kpa) or (0 mmHg) to (200) mmHg.
Display function: the screen of the meter should be able to show systolic pressure, diastolic pressure and pulse values with “mmHg or Kpa”
Measuring error prompt: if the meter fails to measure the blood pressure or pulse, the LCD shall be displayed “Err” to indicate measuring error.
Low battery prompt: When the battery is lower than 5.2V±
0.1V, the symbol of low battery shall be appeared.
Memory function: 60 groups of values of systolic pressure, diastolic pressure and pulse can be saved in the meter, press the memory key once for a previous group of value. Press and hold both left and right memory keys for about three seconds to delete all memories.
Overpressure protection function: When the pressure reaches (40±2) Kpa or (300±15) mmHg, the deflating valve will be open and decreases the pressure to under 2 Kpa or 15 mmHg in 10 seconds.
bigPhoto
 Mr. Endy Chang

Tel: 86-335-8051997
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Hebei Seenmed Medical Instrument Co., Ltd. [China (Mainland)]


Business Type:Manufacturer
Country/Region: China (Mainland)

You May Like: